ATEX products

Series of Antidéflagrant Service flameproof enclosures ready to be equipped

Since 1963, Antidéflagrant Service has designed and built ATEX enclosures for explosive gas and dust atmospheres in zones 1, 2, 21 and 22 in Charny, Burgundy, France: Ex d flameproof ATEX enclosures and Ex e increased safety ATEX enclosures. We also supply the ATEX products that go with them: ATEX cable glands and ATEX signalling. Every ATEX enclosure can be supplied empty, machined or fully equipped and wired in our factory, and our design office adapts it to your application.

Our ATEX product families

All our products

DAS ATEX flameproof enclosureDAS flameproof enclosureEx dIICZones 1, 2, 21, 22IP66−20 °C / +40 °CView productCAS 140 / CAS 140 H ATEX flameproof enclosureCAS 140 / CAS 140 H flameproof enclosureEx dIICZones 1, 2, 21, 22IP66−20 °C / +40 °CView productCAS 160 ATEX flameproof enclosureCAS 160 flameproof enclosureEx dIIBZones 1, 2, 21, 22IP66−20 °C / +40 °CView productCAS 230 ATEX flameproof enclosureCAS 230 flameproof enclosureEx dIIBZones 1, 2, 21, 22IP66−20 °C / +40 °CView productCAS 320 ATEX flameproof enclosureCAS 320 flameproof enclosureEx dIIBZones 1, 2, 21, 22IP66−20 °C / +40 °CView productCAS 430 ATEX flameproof enclosureCAS 430 flameproof enclosureEx dIIBZones 1, 2, 21, 22IP66−20 °C / +40 °CView productCAS IIB+H2 ATEX flameproof enclosure (CAS-A to CAS-H)CAS IIB+H2 flameproof enclosure (CAS-A to CAS-H)Ex dIIB+H2Zones 1, 2, 21, 22IP66, IP67 available−20 °C / +40 °CView productCAS IIB+H2 ATEX enclosure with cathodic protectionCAS IIB+H2 enclosure for cathodic protection systemsEx dIIB+H2Zones 1, 2, 21, 22IP66−20 °C / +40 °CView productCAS-A enclosure, grounding systemCAS-A enclosure, grounding systemEx dIIB+H2Zones 1, 2, 21, 22IP66−20 °C / +40 °CView productEJB ATEX flameproof enclosureEJB flameproof enclosureEx dIIB+H2Zones 1, 2, 21, 22IP66−20 °C / +40 °CView productEJB ATEX flameproof enclosure, UL versionEJB flameproof enclosure, UL versionEx dIIB+H2View productEJC ATEX flameproof enclosure (EJC21 to EJC63)EJC flameproof enclosure (EJC21 to EJC63)Ex dIICZones 1, 2, 21, 22IP66−20 °C / +40 °CView productGUB ATEX enclosureGUB enclosureEx dIICZones 1, 2, 21, 22IP66−20 °C / +40 °CView productBAS-P ATEX control station enclosureBAS-P control station enclosureEx eIICZones 1, 2, 21, 22IP65/66−20 °C / +40 °CView productBAS-P Instrum-Élec ATEX enclosureBAS-P Instrum-Élec enclosureEx eZones 1, 2, 21, 22IP66−20 °C / +40 °CView productBAS-P9 ATEX lighting junction boxBAS-P9 lighting junction boxEx eZones 1, 2, 21, 22IP66−20 °C / +40 °CView productBAS-P9 ATEX lighting switch enclosureBAS-P9 lighting switch enclosureEx eZones 1, 2, 21, 22IP66−20 °C / +40 °CView productBAS-P ATEX increased safety enclosureBAS-P increased safety enclosureEx eZones 1, 2, 21, 22IP66−20 °C / +40 °CView productBAS-P2 grille ATEX enclosureBAS-P2 grille enclosureEx eView productBAS-A ATEX increased safety enclosureBAS-A increased safety enclosureEx eZones 1, 2, 21, 22IP66−20 °C / +40 °CView productBAS-I ATEX increased safety enclosureBAS-I increased safety enclosureEx eZones 1, 2, 21, 22IP66−20 °C / +40 °CView productBASR-P ATEX enclosureBASR-P enclosureEx eb ia/ibIICZones 1, 2, 21, 22IP66−20 °C / +40 °CView productBASR-A ATEX enclosureBASR-A enclosureEx eb ia/ibIICZones 1, 2, 21, 22IP66−20 °C / +40 °CView productBASR-I ATEX enclosureBASR-I enclosureEx eb ia/ibIICZones 1, 2, 21, 22View productPolyamide ATEX cable glandPolyamide ATEX cable glandIICZones 1, 2, 21, 22View productADE1F ATEX cable glandADE1F ATEX cable glandZones 1, 2, 21, 22View productADE4F ATEX cable glandADE4F ATEX cable glandZones 1, 2, 21, 22View productBAD ATEX cable glandBAD ATEX cable glandZones 1, 2, 21, 22View productRAD ATEX cable glandRAD ATEX cable glandZones 1, 2, 21, 22View productBN ATEX cable glandBN ATEX cable glandZones 1, 2, 21, 22View productRN ATEX cable glandRN ATEX cable glandZones 1, 2, 21, 22View productY2 ATEX adaptorY2 ATEX adaptorView productATEX break glass unitATEX break glass unitZones 1, 2, 21, 22View productBC150 ATEX flashing beaconBC150 ATEX flashing beaconEx dIICZones 1, 2, 21, 22IP66−40 °C / +70 °CView productSD150-1 ATEX sounderSD150-1 ATEX sounderEx dIICZones 1, 2, 21, 22IP66−40 °C / +70 °CView product

Ex d and Ex e enclosures, which can house Ex i circuits, in polyester, aluminium alloy, cast iron and 316L stainless steel, supplied empty, machined or fully equipped and wired. All our equipment is ATEX and IECEx certified, and on request INMETRO, UL/CSA and TR CU.

Our ranges

Ex d flameproof enclosures

Parts that could ignite the atmosphere are enclosed in a housing that withstands an internal explosion and prevents it from spreading outside. DAS, CAS 140 to CAS 430, CAS IIB+H2, EJB and EJC ranges, in aluminium alloy, cast iron and 316L stainless steel. View Ex d enclosures

Ex e increased safety enclosures

Additional measures prevent excessive temperatures, arcs and sparks. BAS-P (polyester), BAS-A (aluminium alloy) and BAS-I (316L stainless steel) ranges, more than 75 sizes. View Ex e enclosures

ATEX cable glands and accessories

For armoured and unarmoured cables, with or without compound barrier, in polyamide, nickel-plated brass or 316L stainless steel, plus adaptors. View cable glands

ATEX visual and audible signalling

Indicator lights, flashing beacons, sounders and combined units, built into your assemblies or supplied on their own, on request. View signalling

ATEX luminaires

Luminaires and floodlights for ATEX zones 1, 2, 21 and 22, offered with their datasheets. View the luminaires

Can’t find your product?

We study every technical request. Our design office designs the enclosure and assembly that fit your needs. Request a study

All datasheets are in our Documentation section.